مبدل مدباس (MODBUS) به پروفینت (ProfiNET) اُ دات ODOT دارای ۲ پورت سریال مدل ODOT-PNMO2 V2.1 |
ODOT-PNM02 V2.0 / V2.1: Modbus-RTU/ASCll or Non-standard protocol to ProfiNet Converter
Product Feature:
ODOT-PNM02 V2.1
Modbus (master/slave, RTU/ASCII) to ProfiNET, 2 port serial port (RS485/ RS232 / RS422), supports 50 slots, 200 commands in TIA portal (by configured software), support MAX 60 slaves
♦ Supports protocol conversion between Modbus and PROFINET
♦ Supports 2* RS485/RS232 or 1*RS422
♦ Supports Modbus master or slave, and supports RTU or ASCII
♦ Supports working temperature of -40〜۸۵°C
♦ Supports data area: 2 serial Modbus-RTU/ASCII to PROFIBUS gateway with Max. input 1440 bytesand Max. output 1440 bytes
♦ Supports one key reset
♦ ODOT-PNM02 V2.0 supports Maximum slots: 50
♦ ODOT-PNM02 V2.1 supports 60 slaves (200 read and write commands)
Product Details
ODOT-PNM02 V2.0/V2.1 gateway is a Modbus-RTU/ASCII or non-standard protocol to ProfiNet protocol converter. It can realize the conversion from Modbus-RTU/ASCII or non-standard protocol to ProfiNet. Any device with RS485/RS232/RS422 interface supports Modbus-RTU/ASCII or non-standard protocol can use this product to realize interconnection with industrial bus ProfiNet. Such as: PLC, DCS, remote IO, VFD, scanner, motor start protection device, intelligent high and low voltage electrical appliances, electricity measuring device, intelligent field measuring equipment and instruments, etc.
ODOT-PNM02 V2.0 supports Maximum slots: 50
ODOT-PNM02 V2.1 supports 60 slaves (200 read and write commands)
The product marked as ODOT-PNM02 V2.0 and the GSD file uses the GSD configuration of PNM02L V2.0 in GSDMLV2.33-ODOT-PNM02-V2.0. The product marked as ODOT -PNM02 V2.1, and the GSD file uses the GSD configuration of PNM02L V2.1 in GSDMLV2.33-ODOT-PNM02-V2.0
The difference between PNM02V2.0 and PNM02V2.1 is that V2.0 can be directly uploaded GSD files to TIA Portal for configuration.
The detailed configuration parameters of V2.1 need to be configured with IO CONFIG, and overall parameters settings will be in TIA Portal.
It can select the gateway configuration mode in IO CONFIG
Technical Parameters
Mechanical Property
Shell: Aluminum alloy
Weight: 335g
Dimension: 27.5*110*80mm
Working Temperature: -40〜۸۵°C
Storage Temperature: -55〜۱۲۵°C
Relative Humidity: 5 〜۹۵% (no condensation)
Input Voltage: 9〜۳۶ VDC
Wiring: 3.81mm plug screw terminal
Power: Max. 200mA@24V
Modbus Serial
Port Number: 2
Serial Port: RS485/422/232
Wiring: 3.81mm plug screw terminal
ESD Protection: ±۱۶KV
Rs485 Terminal Resistance: External 120Ω
Data Bits: 7,8
Stop Bits: 1,2
Checkdigit: None, even, odd
Baud Rate: 2400〜۱۱۵۲۰۰bps
Function Code: 01/02/03/04/05/06/15/16
Ethernet Interface
Protocol: PROFINET
ODOT-PNM02 V2.0 supports Maximum slots: 50
ODOT-PNM02 V2.1 supports 60 slaves (200 read and write commands)
Terminal Number: 2ways
Speed: 10/100Mbps self-adaption, Auto-MDI/MDIX
Connector: 8 Pin Rj45
Isolation Protection: Electromagnetic isolation
Main Technical Parameters
Installation: 35mm standard Din-rail
Supports Protocol: PROFINET I/O Device V2.3
PROFINET Data Area: Max. input of 1440 bytes & Max. output of 1440 bytes
ODOT-PNM02 V2.0 supports Maximum slots: 50
ODOT-PNM02 V2.1 supports 60 slaves (200 read and write commands)
Serial Isolation: Optical coupler isolation and power isolation
Serial Number: Supports 2*RS485/RS232 orl*RS422
Serial Terminal Resistance: need external resistance of 120Q
Serial Protocol: Supports Modbus-RTU/ASCII master, Modbus-RTU/ASCII slave
Serial Parameters: Supports baud rate of 1200~115200bps, supports none, even and odd digit check
Stations Supports Modbus 62pcs
Function Code Supports to Modbus ۰۱/۰۲/۰۳/۰۴/۰۵/۰۶/۱۵/۱۶
IPGrade: IP20
Others
Certificate: EMC,CE
Warranty: 3 years
Software
Provide XML documents
Provide debug software