ODOT-S4E2: ۴ Serial Modbus RTU/ASCII to Modbus TCP converter
Product Feature:
♦ Supports protocol conversion between Modbus-RTU and Modbus-TCP
♦ Supports the connection of5 TCP clients simultaneously
♦ ODOT-S2E2 supports 2*RS485
♦ ODOT-S4E2 supports wiring of RS485/RS232/RS422
♦ Each serial port supports Modbus masterand slave
♦ ODOT-S2E2:2 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway
♦ ODOT-S4E2:4 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway
♦ Supports one key reset
♦ Gateway working mode: Transparent transmission, address mapping
Product Details
ODOT-S2E2/S4E2 gateway is a Modbus-RTU/ASCII to Modbus-TCP protocol converter. This product can connect Modbus device to PLC and master computer that supports Modbus-TCP (client) functions. It supports the connection of 5TCPclients simultaneously. And the product adopts aluminum alloy shell with firm design and supports DIN-rail installation. All serial signal provide built-in photoelectric isolation.
Technical Parameters
Mechanical Property
Shell: Aluminum alloy
Weight: 305g(ODOT-S2E2)New
Dimension: 27.5*110*110mm
Working Temperature: -40 〜۸۵°C
Storage Temperature: -55 〜۱۲۵°C
Relative Humidity: 5 〜۹۵%(no condensation)
Input Voltage: 9〜۳۶ VDC
Wiring: 3.81mm plug screw terminal
Power:
Max.l00mA@24V(ODOT-S2E2)
Max.200mA@24V(ODOT-S4E2)
Modbus Serial
Port Number: 2(ODOT-S2E2) ۴(ODOT-S4E2)
Port Protocol: Modbus-RTU/ASCII
Serial Standard: 2*RS485(ODOT-S2E2) OR RS485/RS232/RS422(ODOT-S4E2)
Wiring: 3.81mm plug screw terminal
ESD Protection: ±۱۶KV
Rs485 Terminal Resistance: External 120Ω
Data Bits: 7,8
Stop Bits: 1,2
Check digit: None, even, odd
Baud Rate: 1200~115200 bps
On load: Each serial port theoretically can hang 31 pcs of devices (Rs485/RS422)
Ethernet Interface
Protocol: Modbus-TCP server
Ports Number: 2 pcs (supports switching function)
Communication Rate: l0M/l00Mbps, self-adaptive
Connector: RJ45
Main Technical Parameters
Network Working Mode: Transparent transmission and address mapping are optional, Modbus TCP protocol
Network Protocol: ETHERNET,ARP,IP,TCP,ICMP
TCP Connection: Max. 5 pcs
Supports Slave: Max. 62pcs (no relay)
Mapping Mode Protocol Function Code: 0x01,0x02,0x03,0x04,0x05,0x06,0x0F, 0x10
Modbus Data Storage Area:
0xxxx area (coil): 8192 Bit
Ixxxx area(discrete input): 8192 Bit
۳xxxx area (input register): 2048 Word
۴xxxx area (holding register): 2048 Word
۳xxxx area (system diagnosis area): 263 Word
Ordering Information
ODOT-S2E2: 2 Ports Modbus RTU/ASCII to Modbus TCP Server Gateway, Serial supports RS485,9-36V DC, -40~85°C
ODOT-S4E2: 4 Ports Modbus RTU/ASCII to Modbus TCP Server Gateway, Serial supports RS485,9~36V DC, -40~85°C